Search results for " Ophthalmological"
showing 10 items of 36 documents
Comparison of Immersion Ultrasound, Partial Coherence Interferometry, and Low Coherence Reflectometry for Ocular Biometry in Cataract Patients
2011
PURPOSE: To compare ocular biometry parameters measured with immersion ultrasound, partial coherence interferometry, and low coherence reflectometry in cataract patients. METHODS: Measurements of axial length and anterior chamber depth were analyzed and compared using immersion ultrasound, partial coherence interferometry, and low coherence reflectometry. Keratometry (K), flattest axis, and white-to-white measurements were compared between partial coherence interferometry and low coherence reflectometry. Seventy-eight cataract (LOCS II range: 1 to 3) eyes of 45 patients aged between 42 and 90 years were evaluated. A subanalysis as a function of cataract degree was done for axial length and…
Visual performance of the Akreos Adapt AO intraocular lens in patients with different corneal profiles measured with an adaptive optics visual simula…
2012
AIMS: To evaluate the visual performance of an aberration-free intraocular lens (IOL) in patients with different corneal profiles using adaptive optics visual simulation. METHODS: A crx1 adaptive optics visual simulator was used to simulate the aberration pattern of an aberration-free IOL combined with five corneal profiles: virgin corneas and corneas with low and high myopic ablations and low and high hyperopic ablations. Ten eyes of 10 subjects were evaluated, and monocular distance visual acuity (VA) at 100%, 50% and 10% of contrast was measured. RESULTS: At 100% of contrast, no differences were found in VA values among virgin corneas, low and high myopic ablations and low hyperopic abla…
Semi-automated retinal vessel analysis in nonmydriatic fundus photography.
2013
Purpose Funduscopic assessment of the retinal vessels may be used to assess the health status of microcirculation and as a component in the evaluation of cardiovascular risk factors. Typically, the evaluation is restricted to morphological appreciation without strict quantification. Our purpose was to develop and validate a software tool for semi-automated quantitative analysis of retinal vasculature in nonmydriatic fundus photography. Methods matlab software was used to develop a semi-automated image recognition and analysis tool for the determination of the arterial–venous (A/V) ratio in the central vessel equivalent on 45° digital fundus photographs. Validity and reproducibility of the r…
Medida da profundidade da câmara anterior, distância branco a branco, ângulo da câmara anterior e diâmetro pupilar usando dois dispositivos de imagen…
2014
Purpose: To compare the ocular anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, as measured with two different Scheimpflug imaging devices. Methods: This transversal study included 80 right eyes from 80 subjects aged from 20 to 40 years. Their spherical equivalents ranged from -4.25 to +1.00 diopters (D). Each eye's anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, were measured for far vision using both the Galilei G4 (double Scheimpflug camera) and the Pentacam HR (single Scheimpflug camera) systems. Results: Mean anterior chamber depths were calculated as 3.12 ± 0.23 mm and 3.19 ± 0.24 mm when measured…
Monocular versus binocular pupillometry.
2004
Purpose To quantify differences between monocular and binocular pupil size measurement under scotopic and mesopic conditions. Setting Department of Ophthalmology, Johannes Gutenberg-University, and Department of Medical Biometry, Epidemiology and Informatics, University of Mainz, Mainz, Germany. Methods Computerized dynamic pupillometry (P2000 SA, Procyon Instruments Ltd.) was used at 3 illumination levels: scotopic at 0.03 lux, mesopic low at 0.82 lux, and mesopic high at 6.4 lux. One hundred forty eyes of 70 healthy volunteers without ocular pathology were examined. The subjects were divided into 2 groups. In the first group, the pupil diameter was measured binocularly first. In the secon…
Brimonidine versus dapiprazole: Influence on pupil size at various illumination levels.
2005
To evaluate the influence of dapiprazole versus brimonidine on pupil size at various illumination levels.Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany.In randomized prospective study, 19 healthy volunteers received 2 ophthalmic solutions, dapiprazole and brimonidine, 1 in each eye, for intraindividual comparison. Before and after application, pupil diameter was measured using an infrared binocular pupillometer at 3 illumination levels (0.03, 0.82, and 6.4 lux).Only slight pupil dilation was observed under scotopic conditions after application of both agents. After 20 minutes, the median reduction in pupil width was 1.4 mm for brimonidine and 0.9 mm for dapiprazo…
Does Posterior Capsule Opacification Affect the Results of Diagnostic Technologies to Evaluate the Retina and the Optic Disc?
2014
The visual outcome obtained after cataract removal may progressively decline because of posterior capsular opacification (PCO). This condition can be treated by creating an opening in the posterior lens capsule by Nd:YAG laser capsulotomy. PCO optical imperfections cause several light reflection, refraction, and diffraction phenomena, which may interfere with the functional and structural tests performed in different ocular locations for the diagnosis and follow-up of ocular disease, like macular and optic nerve diseases. Some parameters measured by visual field examinations, scanning laser polarimetry, and optical coherence tomography (OCT) have changed after PCO removal. Imaging quality a…
Diagnostic accuracy of nonmydriatic fundus photography for the detection of glaucoma in diabetic patients.
2015
Purpose. To determine the diagnostic accuracy for glaucoma of a set of criteria with nonmydriatic monoscopic fundus photography (NMFP) in diabetics. Methods. Diabetics recruited from a screening program for diabetic retinopathy and diabetic glaucoma patients recruited from our glaucoma unit were included. Any patient with evidence of diabetic retinopathy was excluded. Diabetic patients had to have no visual field defects to be included as controls. Glaucoma patients had to have a glaucomatous field defect in at least one eye to be included. One NMFP was taken per eye for all subjects. These photographs were evaluated by two masked glaucoma specialists for the presence of the following: bila…
Intrasubject repeatability of corneal power, thickness, and wavefront aberrations with a new version of a dual rotating Scheimpflug–Placido system
2014
Purpose To determine the intrasubject repeatability of a recently introduced dual-camera rotating Scheimpflug–Placido imaging system (Galilei G4) in determining corneal thickness, power, and wavefront aberrations in young healthy subjects. Setting University of Valencia, Valencia, Spain. Design Prospective evaluation of diagnostic technology. Methods The study comprised right eyes of 25 subjects aged 20 to 40 years with a spherical equivalent ranging from −4.25 to +1.00 diopters. The central corneal thickness, thinnest point value and location, anterior and posterior surface curvatures, total corneal power, and corneal wavefront aberrations were measured for distance vision using the dual S…
A novel automated segmentation method for retinal layers in OCT images proves retinal degeneration after optic neuritis.
2015
Aim The evaluation of inner retinal layer thickness can serve as a direct biomarker for monitoring the course of inflammatory diseases of the central nervous system such as multiple sclerosis (MS). Using optical coherence tomography (OCT), thinning of the retinal nerve fibre layer and changes in deeper retinal layers have been observed in patients with MS. Here, we first compare a novel method for automated segmentation of OCT images with manual segmentation using two cohorts of patients with MS. Using this method, we also aimed to reproduce previous findings showing retinal degeneration following optic neuritis (ON) in MS. Methods Based on a 5×5 expansion of the Prewitt operator to efficie…